Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Arq. bras. oftalmol ; 87(2): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527834

ABSTRACT

ABSTRACT Purpose: To translate and validate a questionnaire that evaluates the theoretical knowledge regarding fundus examination. Methods: A 60-item multiple-choice English questionnaire that investigates various aspects of knowledge regarding fundus examination was translated into Portuguese. The process involved translation, back-translation, and evaluation by an expert committee. The resulting questionnaire was applied to final-year medical students and ophthalmology residents. Each included subject answered the questionnaire twice, with an interval of one week between each application. Internal consistency, test-retest reliability, inter-rater reliability, and percentage agreement were calculated. Results: Thirty participants were included (25 medical students and 5 ophthalmology residents). The pass-fail cutoff was calculated at 46, the theoretical false positives were 8.7% and the theoretical false negatives were 2.8%. The observed false positive and false negative rates were 0%. Among the 60 items, test-retest reliability was strong in 17 items, which one had a negative correlation, moderate in 14 items, which one had a negative correlation, and weak in 29 items; inter-rater reliability of 34 items was under 0.4, 17 items were between 0.4 and 0.6, and 8 items were above 0.6. One item had a negative kappa. Among the percent agreement, 10 items were between 40%-60% agreement, 50 were above 60% agreement, and 18 were above 80%. Cronbach's alpha was calculated as 0.674. Conclusions: The translated questionnaire provided a standard instrument for future research and interventions to improve medical education in ophthalmology.


RESUMO Objetivos: Traduzir e validar para o português um questionário para avaliar o conhecimento teórico no exame de fundo de olho. Métodos: Um questionário de múltipla escolha de 60 questões em inglês, ao qual avalia diversos aspetos do conhecimento no exame de fundo de olho, foi traduzido para o português. O processo envolveu uma tradução, re-tradução e avaliação por um comitê de especialistas. O questionário resultante foi aplicado em estudantes de medicina do último ano e médicos-residentes em oftalmologia. Cada indivíduo respondeu o questionário duas vezes, com um intervalo de uma semana entre cada aplicação. A consistência interna, a confiança teste-reteste, a confiança entre avaliadores e a porcentagem de concordâncias foram calculadas. Resultados: Trinta participantes foram incluídos (25 estudantes de medicina e 5 residentes em oftalmologia). A nota de corte para aprovação-reprovação foi calculada em 46, sendo os falsos positivos teóricos de 8,7% e os falsos negativos teóricos 2,8%. No mesmo corte, os falsos positivos e falsos negativos observados foi de 0%. Dentre os 60 itens, a confiança teste-reteste foi forte em 17 itens, sendo que um apresentou uma correlação negativa, moderada em 14 itens, sendo que um apresentou uma correlação negativa, e fraca em 29 itens; a confiança inter-examinador foi inferior a 0,4 em 34 itens, entre 0,4 e 0,6 em 17 itens, e acima de 0,6 em 8 itens. Um dos itens apresentou um valor negativo. A porcentagem de concordância foi entre 40-60% em 10 itens, superior a 60% em 50 itens e acima de 80% em 18 itens. O alfa de Crombach foi calculado com 0,674. Conclusões: O questionário traduzido propicia um instrumento padronizado para futuras pesquisas e intervenções às quais visem aprimorar o ensino em oftalmologia.

2.
Arq. bras. oftalmol ; 87(5): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527853

ABSTRACT

ABSTRACT Purpose: This study aimed to evaluate the classification performance of pretrained convolutional neural network models or architectures using fundus image dataset containing eight disease labels. Methods: A publicly available ocular disease intelligent recognition database has been used for the diagnosis of eight diseases. This ocular disease intelligent recognition database has a total of 10,000 fundus images from both eyes of 5,000 patients for the following eight diseases: healthy, diabetic retinopathy, glaucoma, cataract, age-related macular degeneration, hypertension, myopia, and others. Ocular disease classification performances were investigated by constructing three pretrained convolutional neural network architectures including VGG16, Inceptionv3, and ResNet50 models with adaptive moment optimizer. These models were implemented in Google Colab, which made the task straight-forward without spending hours installing the environment and supporting libraries. To evaluate the effectiveness of the models, the dataset was divided into 70%, 10%, and 20% for training, validation, and testing, respectively. For each classification, the training images were augmented to 10,000 fundus images. Results: ResNet50 achieved an accuracy of 97.1%; sensitivity, 78.5%; specificity, 98.5%; and precision, 79.7%, and had the best area under the curve and final score to classify cataract (area under the curve = 0.964, final score = 0.903). By contrast, VGG16 achieved an accuracy of 96.2%; sensitivity, 56.9%; specificity, 99.2%; precision, 84.1%; area under the curve, 0.949; and final score, 0.857. Conclusions: These results demonstrate the ability of the pretrained convolutional neural network architectures to identify ophthalmological diseases from fundus images. ResNet50 can be a good architecture to solve problems in disease detection and classification of glaucoma, cataract, hypertension, and myopia; Inceptionv3 for age-related macular degeneration, and other disease; and VGG16 for normal and diabetic retinopathy.


RESUMO Objetivo: Avaliar o desempenho de classificação de modelos ou arquiteturas de rede neural convolucional pré--treinadas usando um conjunto de dados de imagem de fundo de olho contendo oito rótulos de doenças diferentes. Métodos: Neste artigo, o conjunto de dados de reconhecimento inteligente de doenças oculares publicamente disponível foi usado para o diagnóstico de oito rótulos de doenças diferentes. O banco de dados de reconhecimento inteligente de doenças oculares tem um total de 10.000 imagens de fundo de olho de ambos os olhos de 5.000 pacientes para oito categorias que contêm rótulos saudáveis, retinopatia diabética, glaucoma, catarata, degeneração macular relacionada à idade, hipertensão, miopia, outros. Investigamos o desempenho da classificação de doenças oculares construindo três arquiteturas de rede neural convolucional pré-treinadas diferentes, incluindo os modelos VGG16, Inceptionv3 e ResNet50 com otimizador de Momento Adaptativo. Esses modelos foram implementados no Google Colab o que facilitou a tarefa sem gastar horas instalando o ambiente e suportando bibliotecas. Para avaliar a eficácia dos modelos, o conjunto de dados é dividido em 70% para treinamento, 10% para validação e os 20% restantes utilizados para teste. As imagens de treinamento foram expandidas para 10.000 imagens de fundo de olho para cada tal. Resultados: Observou-se que o modelo ResNet50 alcançou acurácia de 97,1%, sensibilidade de 78,5%, especificidade de 98,5% e precisão de 79,7% e teve a melhor área sob a curva e pontuação final para classificar a categoria da catarata (área sob a curva=0,964, final=0,903). Em contraste, o modelo VGG16 alcançou uma precisão de 96,2%, sensibilidade de 56,9%, especificidade de 99,2% e precisão de 84,1%, área sob a curva 0,949 e pontuação final de 0,857. Conclusão: Esses resultados demonstram a capacidade das arquiteturas de rede neural convolucional pré-treinadas em identificar doenças oftalmológicas a partir de imagens de fundo de olho. ResNet50 pode ser uma boa solução para resolver problemas na detecção e classificação de doenças como glaucoma, catarata, hipertensão e miopia; Inceptionv3 para degeneração macular relacionada à idade e outras doenças; e VGG16 para retinopatia normal e diabética.

3.
Rev. bras. oftalmol ; 82: e0036, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1449766

ABSTRACT

RESUMO Objetivo Avaliar os mapeamentos de retina realizados em interconsultas oftalmológicas, analisando as prevalências de alterações encontradas e comparando-as com o motivo da interconsulta. Métodos Estudo transversal, com dados encontrados durante exame de mapeamento de retina de pacientes internados ou em atendimento no pronto-socorro. Os dados analisados de cada paciente foram idade, sexo, especialidade médica solicitante, motivo da interconsulta e achados do exame fundoscópico. Resultados Foram avaliados 104 pacientes, com prevalência de alterações ao exame em 43,27%. Os motivos mais frequentes de solicitação de avaliação oftalmológica foram trauma (16,35%) e alterações neurológicas (15,38%). O achado com maior prevalência foi o edema de papila, presente em 17,3% das avaliações gerais. Outros achados muito prevalentes foram as retinopatias diabética e hipertensiva, ambas com 11,53% na avaliação geral, mas com 83,3% e 53,84% de prevalência nos pacientes cujos motivos da consulta foram diabetes mellitus descompensada e crise hipertensiva, respectivamente. Conclusão O edema de papila e as retinopatias diabética e hipertensiva foram as alterações mais prevalentes, o que demonstra a importância do atendimento multidisciplinar sempre que possível, com maior atenção aos pacientes hipertensos e diabéticos.


ABSTRACT Objective To evaluate the indirect ophthalmoscopy performed in ophthalmologic consultations, analyzing the prevalence of the study and comparing them with the reason for the consultation. Methods Cross-sectional study, with data found during the indirect ophthalmoscopy exam of inpatients or in emergency room care. The data analyzed for each patient was sex, the requested medical age, the reason for the consultation and the funduscopic examination findings. Results One hundred and four patients were evaluated and 43.27% of patients with a prevalence of changes in the exam. The most requested reasons for requesting ophthalmologic evaluation were trauma (16.35%) and neurological alterations (15.38%). The most prevalent finding was papillary edema, representing 17.3% of the general estimates. Other very prevalent findings were diabetic and hypertensive retinopathies, both with 11.53% in the general assessment, but with 83.3% and 53.84% prevalence in patients whose reasons for consultation were decompensated DM and hypertensive crisis, respectively. Conclusions Papillary edema and diabetic and hypertensive retinopathies were the most prevalent alterations, which demonstrates the importance of multidisciplinary care whenever possible, with greater attention to hypertensive and diabetic patients.

4.
Rev. bras. med. fam. comunidade ; 17(44): 2970, 20220304.
Article in Portuguese | LILACS, ColecionaSUS | ID: biblio-1379769

ABSTRACT

A oftalmoscopia direta é um exame utilizado para diagnóstico e rastreamento de doenças da retina, do disco óptico e do humor vítreo no contexto da atenção primária à saúde. Estudos demonstram que é uma prática pouco utilizada regularmente por médicos de família e comunidade. O objetivo deste estudo é identificar barreiras para a realização da oftalmoscopia por médicos da referida especialidade. Este estudo utilizou metodologia qualitativa, baseada em entrevista semiestruturada com médicos de família e comunidade e posterior análise temática. Demonstrou-se que as barreiras para a realização de oftalmoscopia direta incluem dificuldade no manejo do oftalmoscópio e na dilatação pupilar, pouco conhecimento da anatomia ocular, sentimento de insegurança na realização e na interpretação de achados, percepção de que seria um exame mais bem realizado por um especialista, falta de formação e experiência prática na graduação e na residência médica, percepção de pouca utilidade ou resolutividade, dificuldade em adequar o ambiente para a realização do exame, ausência de aparelho e colírios midriáticos nas unidades de saúde, aumento no tempo de consulta, ausência de fluxos de encaminhamento mediante achados alterados, presença de serviços de teleoftalmologia e ausência de treinamento da equipe multiprofissional.


Introduction: Direct ophthalmoscopy is an examination performed for the diagnosis and screening of diseases of the retina, optic disc, and vitreous humor in the context of primary health care. Studies show that this practice is rarely used by primary care physicians. Objective: The aim of this study is to identify barriers for primary care physicians to perform ophthalmoscopy. Methods: This study used a qualitative methodology based on a semi-structured interview with primary care physicians with subsequent thematic analysis. Results: It was verified that barriers to performing direct ophthalmoscopy include difficulty in handling the ophthalmoscope and pupil dilation, little knowledge of eye anatomy, feeling of insecurity in performing and interpreting findings, perception that the examination would be better performed by a specialist, lack of training and practical experience in undergraduate program and medical residency, perception of little use or resolution, difficulty in adjusting the room environment for the examination, absence of equipment and mydriatics in health units, increase in consultation time, absence of referral flows when facing altered findings, presence of teleophthalmology services and lack of training of the multidisciplinary team. Conclusions: Barriers to performing ophthalmoscopy by primary care physicians include emotional, behavioral, cognitive, educational, and work-environment aspects.


Introducción: La oftalmoscopia directa es un examen que se utiliza para el diagnóstico y rastreo de enfermedades de la retina, el disco óptico y el humor vítreo en el contexto de la atención primaria de salud. Los estudios demuestran que es una práctica poco utilizada habitualmente por los médicos de familia y comunidad. Objetivo: El objetivo de este estudio es identificar barreras del porqué los médicos de familia y comunidad no realizan oftalmoscopias. Métodos: Esta investigación está basada en una entrevista semiestructurada com médicos de familia y comunidad con posterior análisis temático. Resultados: Se ha demostrado que las barreras para realizar oftalmoscopia directa incluyen dificultad en el manejo del oftalmoscopio y dilatación pupilar, poco conocimiento de la anatomía ocular, sensación de inseguridad en la realización e interpretación de los hallazgos, percepción de que sería un mejor examen por parte de un especialista, falta de formación y experiencia práctica en licenciatura y residencia médica, percepción de poco uso o resolución, dificultad para ajustar el ambiente para el examen, ausencia de aparatos y gotas midriáticas en las unidades de salud, aumento del tiempo de consulta, ausencia de flujo derivación a hallazgos alterados, presencia de servicios de teleoftalmología y falta de formación del equipo multidisciplinario. Conclusiones: Barreras para la oftalmoscopia directa por médicos de familia y de la comunidad incluyen aspectos emocionales, conductuales, cognitivos, educativos y del entorno laboral.


Subject(s)
Humans , Male , Female , Ophthalmoscopy , Fundus Oculi , Primary Health Care , Family Practice
5.
Rev. bras. educ. méd ; 45(2): e092, 2021. tab
Article in Portuguese | LILACS | ID: biblio-1279841

ABSTRACT

Resumo: Introdução: O ensino médico vem passando por transformações nas últimas décadas. Objetivos educacionais tendem a se alterar com os avanços tecnológicos recentes, em especial na área de tecnologias de informação. Objetivo: Esta pesquisa aborda o exame do fundo de olho explorando e analisando as dificuldades dos estudantes de Medicina na execução desse componente do exame clínico e busca propor diretrizes para seu ensino na graduação médica. Métodos: Trata-se de uma pesquisa qualitativa com técnicas de observação direta e entrevistas com análise de conteúdo em uma população de estudantes do internato da Universidade do Estado do Pará (Uepa), na cidade de Marabá. Na avaliação de conteúdo utilizaram-se recursos do programa livre de análise de texto Iramuteq. Resultados: Dos 21 estudantes voluntários participantes da pesquisa, apenas dois relataram experiência anterior com oftalmoscópio direto (9,52%) e um aluno havia participado de campanha com uso de dispositivo portátil para registro da imagem do fundo de olho (4,8%). As atividades da pesquisa incluiram discussão de casos clínicos, realização de oftalmoscopias diretas em pacientes voluntários e análise de retinografias. Na análise dos textos correspondentes às entrevistas foram categorizadas quatro classes geradas pelo programa Iramuteq, realçando-se o valor da integração de teoria e prática no depoimento dos alunos. Conclusão: Programas de treinamento com integração de teoria e prática e valendo-se de princípios de aprendizagem significativa podem contribuir para prover competência ao estudante de Medicina para o exame de fundo de olho, adequando-se ao surgimento de novas tecnologias.


Abstract: Introduction: Medical education has undergone changes in recent decades. Educational objectives tend to change with recent technological advances, especially in the area of information technologies. Objective: This research addresses the examination of ocular fundus by exploring and analyzing the difficulties medical students encounter in relation to this component of the clinical examination and seeks to propose guidelines for its teaching in undergraduate medical training. Method: Qualitative research with direct observation techniques and interviews with content analysis with a population of students at the University of the State of Pará (UEPA), in the city of Marabá. Content analysis used resources from the free text analysis program Iramuteq. Results: Of the 21 volunteer students participating in the research, only two reported previous experience with direct ophthalmoscope (9.52%) and one student had participated in a campaign using a portable device to record the fundus image (4.8%). Research activities included discussion of clinical cases, performing direct ophthalmoscopies in volunteer patients and retinography analysis. In the analysis of the texts corresponding to the interviews, four classes generated by the Iramuteq program were categorized, highlighting the value of theoretical and practical integration in the students' testimony. Conclusion: Training programs with theoretical and practical integration using meaningful learning concepts can help qualify medical students in the ocular fundus exam, adapting to the emergence of new technologies.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Ophthalmology/education , Ophthalmoscopy/methods , Education, Medical, Undergraduate/methods , Retinal Diseases/diagnosis , Clinical Competence , Problem-Based Learning , Diagnostic Tests, Routine , Fundus Oculi
6.
Arq. bras. oftalmol ; 82(5): 412-416, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019424

ABSTRACT

ABSTRACT Purpose: To evaluate the usefulness of fundus autofluorescence imaging of diabetic patients without retinopathy to investigate early retinal damage. Methods: Fundus autofluorescence images of patients with type 2 diabetes mellitus without retinopathy (diabetic group) and age-sex matched healthy patients (control group) were recorded with a CX-1 digital mydriatic retinal camera after detailed ophthalmologic examinations. MATLAB 2013a software was used to measure the average pixel intensity and average curve width of the macula and fovea. Results: Fifty-six eyes of 28 patients, as the diabetic group, and 54 eyes of 27 healthy patients, as the control group, were included in this study. The mean aggregation index was 168.32 ± 37.18 grayscale units (gsu) in the diabetic group and 152.27 ± 30.39 gsu in the control group (p=0.014). The mean average pixel intensity value of the fovea was 150.87 ± 35.83 gsu the in diabetic group and as 141.51 ± 31.10 gsu in the control group (p=0.060). The average curve width value was statistically higher in the diabetic group than in the control group (71.7 ± 9.2 vs. 59.4 ± 8.6 gsu, respectively, p=0.03). Conclusion: Fundus autofluorescence imaging analysis revealed that diabetic patients without retinopathy have significant fluorescence alterations. Therefore, a noninvasive imaging technique, such as fundus autofluorescence, may be valuable for evaluation of the retina of diabetic patients without retinopathy.


RESUMO Objetivo: Avaliar a utilidade da autofluorescência do fundo de olho de pacientes diabéticos sem retinopatia para investigar lesões precoces na retina. Métodos: Imagens de autofluorescência do fundo de olho de pacientes com diabetes mellitus do tipo 2 sem retinopatia (grupo diabético) e indivíduos saudáveis pareados por idade e sexo (grupo controle) foram registrados com uma câmera retiniana digital midriática CX-1 após exames oftalmológicos detalhados. O software MATLAB 2013a foi usado para medir a intensidade média do pixel e a largura média da curva da mácula e fóvea. Resultados: Cinquenta e seis olhos de 28 pacientes, como o grupo diabético, e 54 olhos de 27 indivíduos saudáveis, como grupo controle, foram incluídos neste estudo. O índice médio de agregação foi de 168,32 ± 37,18 unidades de escala de cinza (gsu) no grupo diabético e em 152,27 ± 30,39 gsu no grupo controle (p = 0,014). O valor médio da intensidade de pixel na fóvea foi de 150,87 ± 35,83 gsu no grupo diabético e de 141,51 ± 31,10 gsu no grupo controle (p=0,060). O valor médio da largura da curva foi estatisticamente maior no grupo diabético do que no grupo controle (71,7 ± 9,2 vs. 59,4 ± 8,6 gsu, respectivamente; p = 0,03). Conclusão: A análise por imagens de autofluorescência de fundo de olho revelou que pacientes diabéticos sem retinopatia apresentam alterações significativas de fluorescência. Portanto, uma técnica de imagem não invasiva, como a autofluorescência de fundo de olho, pode ser valiosa para a avaliação da retina de pacientes diabéticos sem retinopatia.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Retinal Diseases/diagnostic imaging , Diabetes Mellitus, Type 2/physiopathology , Diabetic Retinopathy/diagnosis , Optical Imaging/methods , Fundus Oculi , Retinal Diseases/physiopathology , Fluorescein Angiography/methods , Visual Acuity , Case-Control Studies
7.
Rev. bras. oftalmol ; 78(2): 137-140, mar.-abr. 2019. graf
Article in Portuguese | LILACS | ID: biblio-1003571

ABSTRACT

Resumo Esclerite Posterior (EP) é uma inflamação do segmento escleral posterior, de etiologia inflamatória ou infecciosa, pouco diagnosticada, com evolução rápida, progressiva e irreversível com severo comprometimento visual, principalmente se o diagnóstico e o tratamento da (EP) não forem realizados a tempo hábil. A dor ocular, dor à movimentação ocular, cefaléia e embaçamento visual são os principais sinais e sintomas. Pode ser de causa Idiopática ou associada a doença sistêmica em até 45% dos caso. A Artrite Reumatoide é descrita como a associação mais comum. Causas infecciosas podem estar presente tais como: Herpes Simples, Herpes Zoster Oftálmico, Sífilis e Tuberculose. A bilateralidade pode ocorrer em até 35% dos casos sendo mais prevalente em mulheres a partir da quinta década de vida.


Abstract Posterior Scleritis (PS) is an inflammation of the posterior scleral segment, of low inflammatory or infectious etiology, with a rapid, progressive and irreversible evolution with severe visual impairment, especially if the diagnosis and treatment of (PS) are not performed in time skillful. Ocular pain, eye movement pain, headache and visual haze are the main signs and symptoms. It can be of idiopathic cause or associated with systemic disease in up to 45% of the cases. Rheumatoid arthritis is described as the most common association. Infectious causes may be present such as: Simple Herpes, Ophthalmic Herpes Zoster, Syphilis and Tuberculosis. Bilaterality can occur in up to 35% of cases being more prevalent in women from the fifth decade of life.


Subject(s)
Humans , Female , Middle Aged , Scleritis/diagnosis , Scleritis/drug therapy , Posterior Eye Segment/pathology , Pain , Methylprednisolone/administration & dosage , Fluorescein Angiography , Ultrasonography , Tomography, Optical Coherence , Fundus Oculi
8.
Rev. bras. oftalmol ; 77(1): 38-42, jan.-fev. 2018. graf
Article in Portuguese | LILACS | ID: biblio-899112

ABSTRACT

Resumo Esclerite posterior é uma doença inflamatória ocular que acomete a esclera e cujo diagnóstico é difícil. A clínica da doença envolve a piora da qualidade visual com dor ocular e achados do segmento posterior, como descolamento de retina seroso, dobras de coroide, edema de disco óptico e espessamento escleral. Deve-se ficar atento aos achados sistêmicos, pois, muitas vezes, está associada a doenças como artrite reumatoide, lúpus eritematoso sistêmico, doença inflamatória intestinal e doenças infecciosas, como sífilis e tuberculose. Este trabalho objetiva descrever dois casos: uma paciente com quadro de esclerite posterior bilateral simultânea, sem alterações sistêmicas correlacionadas com a doença. A apresentação bilateral é incomum nesta patologia; e outro caso de esclerite anterior e posterior unilateral recorrente.


Abstract Posterior scleritis is an ocular inflammatory disease that affects the sclera e whose diagnosis is difficult. The main clinical manifestations are worsening of visual quality, ocular pain and finding in the posterior segment, such as serous retinal detachment, choroidal folds, optic disc edema and sclera thickening. We should award for systemic findings, because it is often accompanied by rheumatoid arthritis, systemic lupus erythematosus, inflammatory bowel disease and infections, such as syphilis and tuberculosis.This paper aims to describe two cases: one patient with simultaneous bilateral posterior scleritis without systemic alterations correlated with the disease. Bilateral presentation is uncommon in this pathology; and another case of recurrent unilateral anterior and posterior scleritis.


Subject(s)
Humans , Female , Adult , Scleritis/diagnosis , Posterior Eye Segment/pathology , Ophthalmoscopy , Orbit/diagnostic imaging , Recurrence , Methylprednisolone/administration & dosage , Magnetic Resonance Imaging , Visual Acuity , Tomography, X-Ray Computed , Scleritis/drug therapy , Ultrasonography , Pulse Therapy, Drug , Slit Lamp Microscopy , Fundus Oculi , Intraocular Pressure
9.
J. health inform ; 8(supl.I): 737-746, 2016. ilus, tab
Article in Portuguese | LILACS | ID: biblio-906590

ABSTRACT

O glaucoma é uma das doenças que mais causam cegueira em todo o mundo. O Conselho Brasileiro de Oftalmologia (CBO) estima que no Brasil existam 985 mil portadores de glaucoma com mais de 40 anos de idade. A utilização de sistemas CAD e CADx tem contribuído para aumentar as chances de detecção e diagnósticos corretos,auxiliando os especialistas na tomada de decisões sobre o tratamento do glaucoma. OBJETIVO: Apresentar um método para diagnóstico do glaucoma em retinografias utilizando o LBP para representar a região do disco ótico, funções geoestatísticas para descrever padrões e o MVS para classificar as imagens. MÉTODOS: Executado em 3 etapas: Representação da imagem (1), Extração de Características com geoestatística (2) e Classificação e Validação (3). RESULTADOS: Foram obtidos 88% de especificidade, 82% de sensibilidade e 84% de acurácia no diagnóstico do glaucoma. CONCLUSÃO: O método mostrou-se promissor como uma forma de auxílio ao diagnóstico de glaucoma.


Glaucoma is one of the diseases that more cause blindness worldwide. The Brazilian Council of Ophthalmology (CBO) estimates that in Brazil there are 985,000 people with glaucoma over 40 years old. The use of CAD and CADxsystems has contributed to increase the chances of detection and correct diagnoses, they provide, helping specialists inmaking decisions on glaucoma treatment. OBJECTIVE: To introduce a method for diagnosing glaucoma in fundus imageusing the LBP to represent the optic disk region, geostatistical functions to describe patterns and SVM to classify the images. METHODS: Run in 3 steps: Image representation (2), Feature extraction with geostatistic (3) and Classification and Validation (4). RESULTS: we obtained 88% specificity, 82% sensitivity and 84% accuracy in the diagnosis of glaucoma. CONCLUSION: The method has shown promise as a tool to aid the diagnosis of glaucoma.


Subject(s)
Humans , Image Processing, Computer-Assisted , Glaucoma/diagnosis , Fundus Oculi , Congresses as Topic
10.
Rev. bras. oftalmol ; 74(5): 325-328, set.-out. 2015. ilus
Article in English | LILACS | ID: lil-757457

ABSTRACT

The authors make a review of drusenoid retinal pigment epithelium detachments(DPDs), a form of retinal pigment epithelium detachment(PED) that evolves from confluent and large soft drusen.Drusenoidretinal pigment epithelial detachments are a recognized element of the "dry" AMD. Until now, no treatment is indicated in drusenoid PEDs. The authors describe the clinical characteristics of drusenoid retinal pigment epithelium detachments (DPEDs) and make a review of the DPEDs related in the international literature. We related in this revision paper the multimodal advanced image exams in two cases of dusenoid retinal pigment epithelium detachments (DPEDs) and the general characteristics of thisfinding associated with Dry Macular degeneration.Upon examination of the ocular fundusDPEDs emerge as well-circumscribed yellow or yellow–white elevations of the RPE that are usually found within the macula.They may show scalloped borders and a slightly irregular surface. When visualized using fluorescein angiography (FA),DPEDs are typically described as faint hyper-fluorescent in the early phase followed by a slow increase in fluorescence throughout the transit stage of the study without late leakage. With optical coherence tomography (OCT), drusenoid PEDs usually show a smooth contour of the detached hyperreflective RPE band that may have an undulating appearance.Drusenoid PEDs encompass far above the ground possibility type of "dry" AMD that develops in relationship with large confluent soft drusen.At this point no treatment is utilized in drusenoid retinal pigment epithelium detachment(DPEDs).


Os autores fazem uma revisão do descolamento do epitélio pigmentar tipo drusenoide e apresentam dois casos desta patologiaassociada à degeneração macular relacionadaà idade descrevendo seus achados em avançados exames com imagem da retina.Neste artigo de revisão da literatura sobre os achados característicos dodescolamento do epitélio pigmentar tipodrusenoide e sua evolução descrevemos os achados de dois casosassociados à degeneração macular relacionada à idade, forma seca, utilizando exames como SD-OCT, fundusautofluorescencia e angiografia com indocianinaverde, além de retinografiacolorida e fluoresceínica. Odescolamento do epitélio pigmentar tipo druside evolui á partir de drussas moles confluentes presentes na degeneração macular relacionada à idade e é também associado a outras doenças retinianas. Até este momento não há tratamento para esta forma da doença.


Subject(s)
Humans , Fluorescein Angiography , Fundus Oculi , Macular Degeneration , Retinal Detachment , Retinal Drusen , Prospective Studies
11.
Rev. bras. oftalmol ; 73(6): 386-388, Nov-Dec/2014. graf
Article in English | LILACS | ID: lil-741906

ABSTRACT

A 58-year-old woman presented with rash over the left side of the face and intense acute uveitis. Following careful review of the symptoms and dilated fundus examination unilateral optic neuritis was discovered. The rash was typical of varicella zoster dermatitis. Patients presenting with herpes zoster ophthalmicus should always undergo dilated fundus examination, as there is a potential risk of unexpected posterior segment inflammation. Early diagnosis and prompt treatment can avoid visual sequelae.


Paciente de 58 anos de idade apresentando erupção cutânea no lado esquerdo da face e intensa uveíte unilateral. Após cuidadosa revisão dos sintomas e exame de fundo do olho foi detectada neurite óptica. O rash era típico de dermatite por varicella zoster. Pacientes apresentando quadro de herpes zoster oftálmico devem ser submetidos ao exame de fundo do olho devido ao risco de inesperada inflamação do segmento posterior. Diagnóstico precoce e tratamento imediato podem evitar danos visuais.


Subject(s)
Humans , Female , Middle Aged , Chickenpox/complications , Optic Neuritis/diagnosis , Optic Neuritis/etiology , Herpes Zoster Ophthalmicus/complications , Herpes Zoster Ophthalmicus/diagnosis , Herpesvirus 3, Human/immunology , Optic Nerve/pathology , Optic Nerve/diagnostic imaging , Sulfonamides/therapeutic use , Timolol/therapeutic use , Virus Activation , Prednisone/therapeutic use , Fluorescein Angiography , Optic Neuritis/drug therapy , Optic Neuritis/virology , Uveitis, Anterior/diagnosis , Uveitis, Anterior/virology , Ocular Hypertension/etiology , Ocular Hypertension/drug therapy , Herpes Zoster Ophthalmicus/drug therapy , Herpes Zoster Ophthalmicus/virology , Adrenal Cortex Hormones/therapeutic use , Tomography, Optical Coherence , Slit Lamp Microscopy , Valacyclovir/therapeutic use , Fundus Oculi , Intraocular Pressure/physiology , Mydriatics/therapeutic use
12.
Arq. bras. oftalmol ; 76(5): 274-277, set.-out. 2013. ilus
Article in English | LILACS | ID: lil-690603

ABSTRACT

PURPOSE: To investigate the correlation between the measurements of the cup/retrobulbar optic nerve diameter (C/OND) proportion obtained by high-resolution 20-MHz B-mode ultrasound (US) and those of the cup/disc ratio (C/D) obtained by fundus biomicroscopy (BIO) and optical coherence tomography (OCT). METHODS: Thirty eyes of 15 glaucomatous patients with any C/D proportion were studied. All patients underwent examination of the vertical C/D by BIO with a 78D lens and time-domain OCT analysis, as well as the vertical C/OND proportion using 20-MHz US measurements. All data were analyzed by correlation and agreement tests. RESULTS: The Spearman test showed a strong correlation between C/D results obtained by BIO and the measurements of C/OND (US) (r=0.788, p<0.0001), and with C/D obtained by OCT (r=0.8529, p<0.0001). However, comparison of C/D results obtained with OCT to those obtained by with C/OND (US) showed only a moderate correlation (r=0.6727, p<0.0001). Bland-Altman analysis did not show good agreement between C/D (BIO) and C/OND (US). CONCLUSIONS: The results demonstrate that B-mode ultrasound examination with a 20 MHz probe can be a good additional method for the evaluation of the C/D ratio in glaucomatous patients, and may be considered as an alternative gross tool in glaucomatous patients with optic media opacities.


OBJETIVOS: Verificar a correlação entre os achados da relação escavação/diâmetro do nervo óptico retrobulbar (E/DNO) obtidos pelo exame de ultrassom (US) modo B de alta resolução com sonda de 20 MHz e a relação escavação/disco (E/D) obtidos pela biomicroscopia de fundo de olho (BIO) e pela tomografia de coerência óptica (OCT). MÉTODOS: Foram analisados 30 olhos de 15 pacientes com diagnóstico de glaucoma com qualquer proporção da relação E/D. Todos os pacientes foram submetidos ao exame de BIO, com lente 78D, e de OCT, com tecnologia de domínio temporal, para a análise da relação E/D vertical e exame de US modo B, com sonda de 20 MHz, para determinação da proporção E/DNO vertical. Todos os resultados foram analisados por métodos de correlação e concordância. RESULTADOS: Observou-se forte correlação entre as medidas E/D obtidas pela BIO, e as medidas E/DNO (US) (r=0,788; p<0,0001), e com as medidas E/D obtidas pelo OCT (r=0,8529; p<0,0001). Porém, a análise entre as medidas E/DNO (US) e E/D (OCT) mostrou apenas níveis moderados de correlação (r=0,6727, p<0,0001). O teste de Bland-Altman não mostrou bons níveis de concordância entre E/D (BIO) e E/DNO (US). CONCLUSÕES: Os resultados demonstraram que o exame de US modo B com sonda de 20 MHz pode ser um bom método adicional para avaliar a relação E/D de pacientes com glaucoma, a ser considerado como uma ferramenta alternativa na avaliação de pacientes glaucomatosos com opacidades dos meios ópticos.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Glaucoma , Microscopy, Acoustic/methods , Optic Nerve , Corneal Opacity , Cross-Sectional Studies , Fundus Oculi , Optic Disk , Statistics, Nonparametric , Tomography/methods
13.
Rev. bras. oftalmol ; 72(2): 122-124, mar.-abr. 2013. ilus
Article in Portuguese | LILACS | ID: lil-678380

ABSTRACT

A fosseta de papila do nervo óptico e o microburaco macular são duas patologias raras, cuja probabilidade de coexistência se torna extremamente baixa, embora não haja relação fisiopatológica entre ambas, descreveremos um caso de associação das mesmas, acometendo comumente um olho, a fim de analisar as manifestações clínicas, os exames de OCT, angiografia, retinografia, biomocroscopia, o tratamento e a correlação entre ambas patologias.


Optic disc pit and macular microhole are two rare pathologies with an extremely low likelihood of coexistence, this paper will report an association of both pathologies in the same eye with the purpose of analyzing clinical manifestations, tests, angiography, OCT, retinography, biomocroscopy, treatment outcome and the connection between the optic disc pit and macular microhole.


Subject(s)
Humans , Female , Adult , Retinal Detachment/therapy , Optic Disk/abnormalities , Fundus Oculi , Retinal Perforations/therapy , Tomography, Optical Coherence
14.
Arq. bras. oftalmol ; 73(3): 231-234, jun. 2010. ilus, graf
Article in Portuguese | LILACS | ID: lil-555062

ABSTRACT

Objetivo: Verificar a frequência de assimetrias superiores a 0,2 na razão escavação/disco em uma população de adolescentes. Métodos: Retinografias de ambos os olhos de 123 jovens foram digitalizadas na resolução de 300 pixels por polegada (300 dpi), 8 bits, padrão de cor RGB. Para a realização das medidas foi utilizado o software Image J, versão 1.42, desenvolvido pelo National Institute of Health (NIH), plataforma Java versão 1.6. Resultados: Os valores das diferenças, entre os dois olhos do mesmo indivíduo, na razão das medidas do diâmetro vertical da escavação/diâmetro vertical do disco óptico variaram de 0 a 0,30. A média das diferenças foi 0,07, a mediana 0,06 e o desvio padrão 0,05. Assimetrias de até 0,06 apresentaram frequência de 54,4 por cento e assimetrias de até 0,1 estiveram presentes em 79,7 por cento da amostra. Dois indivíduos (1,63 por cento) apresentaram assimetrias superiores a 0,2. Conclusão: A frequência de assimetrias no grupo de adolescentes estudado é similar à encontrada em estudos realizados com população adulta normal.


Purpose: To determine the frequency of asymmetries greater than 0.2 in the cup-to-disc ratio of a population of adolescents. Methods: Fundus photographs of both eyes of 123 adolescents were digitized at the resolution of 300 pixels per inch (300 dpi), 8 bits, with a RBG color pattern. The measurements were performed using the Image J software, version 1.42, developed by the National Institutes of Health (NIH), Java platform version 1.6. Results: The values of the differences in the cup-to-disc ratio between the two eyes of the same individual ranged from 0 to 0.30. The mean difference was 0.07, the median 0.06 and the standard deviation 0.05. About 54.4 percent of the studied population had asymmetries up to 0.06 and 79.7 percent had asymmetries up to 0.1. Two individuals presented asymmetries of more than 0.2, corresponding to 1.63 percent of the evaluated subjects. Conclusion: The frequency of asymmetries in the group of adolescents studied was similar to that detected in studies of the normal adult population.


Subject(s)
Adolescent , Female , Humans , Male , Fundus Oculi , Optic Disk/anatomy & histology , Cross-Sectional Studies , Image Interpretation, Computer-Assisted , Reference Values
15.
Rev. Soc. Bras. Med. Trop ; 43(1): 36-40, Jan.-Feb. 2010. tab, ilus
Article in Portuguese | LILACS | ID: lil-540510

ABSTRACT

INTRODUÇÃO: Descrever os achados fundoscópicos em pacientes com AIDS e neurotoxoplasmose em fase ativa. MÉTODOS: Foi desenvolvido estudo prospectivo tipo série de casos incluindo 70 pacientes, de ambos os sexos, com idade variando de 20 a 63 anos, internados nas enfermarias de três hospitais públicos da Cidade do Recife, Pernambuco, com diagnósticos de AIDS e neurotoxoplasmose firmados segundo os critérios do Centers for Disease Control and Prevention (1992), no período de janeiro a outubro de 2008. Os pacientes se caracterizavam por: primeiro episódio de neurotoxoplasmose (65; 92,9 por cento) ou recidiva (5; 7,1 por cento); desconhecimento de ter AIDS (23; 32,9 por cento), contagem média de linfócitos T CD4 de 139,8 ± 3,04 células/mm3 e carga viral média igual a 137.080 ± 39.380 cópias/mL. Todos foram submetidos a exame oftalmológico, consistindo de: inspeção ocular; aferição da acuidade visual; investigação da função muscular extrínseca ocular e fundoscopia, empregando oftalmoscópio indireto binocular (modelo OHN 3.5 (Eyetec®) e lente externa de 20 dioptrias (Volk®). RESULTADOS: Os achados consistiram em: exsudatos algodonosos retinianos (8,6 por cento), constricção arteriolar difusa leve (8,6 por cento); lesões de retinocoroidite cicatricial, características de toxoplasmose ocular (5,7 por cento), atrofia do epitélio pigmentar retiniano (2,9 por cento), descolamento da retina (2,9 por cento), aumento de escavação papilar (1,4 por cento), degeneração periférica retiniana (1,4 por cento), macroaneurisma (1,4 por cento), papiledema bilateral (1,4 por cento), tração vítreo-retiniana (1,4 por cento). CONCLUSÕES: Pacientes com AIDS e neurotoxoplasmose podem apresentar alterações fundoscópicas características da toxoplasmose ocular, na forma ativa ou cicatricial, relacionadas ao HIV ou, ainda, a outras doenças oportunistas ou sistêmicas, podendo ser de grande auxílio num tratamento integral do paciente por uma equipe multiprofissional.


INTRODUCTION: To describe fundoscopic findings among patients with AIDS and active-phase neurotoxoplasmosis. METHODS: A prospective study of case series type was developed, including 70 patients of both sexes and ages ranging from 20 to 63 years who were admitted to the wards of three public hospitals in the city of Recife, Pernambuco, Brazil, from January to October 2008, with diagnoses of AIDS and neurotoxoplasmosis determined according to the criteria of the Centers for Disease Control and Prevention (1992). The patients were characterized by a first episode of neurotoxoplasmosis (65; 92.9 percent) or recurrence (5; 7.1 percent), unawareness of having AIDS (23; 32.9 percent), mean T CD4+ count of 139.8 ± 3.04 lymphocytes/mm³ and mean viral load of 137,080 ± 39,380 copies/ml. All patients underwent ophthalmological examination consisting of ocular inspection, gauging of visual acuity, investigation of ocular extrinsic muscle function and fundoscopy using a binocular indirect ophthalmoscope (model OHM 3.5 Eyetec®) and external lens of 20 diopters (Volk®). RESULTS: The findings consisted of retinal cotton-wool spot exudates (8.6 percent), slight diffuse arteriolar constriction (8.6 percent), retinochoroiditis scars characteristic of ocular toxoplasmosis (5.7 percent), atrophy of retinal pigment epithelium (2.9 percent), retinal detachment (2.9 percent), increased papillary excavation (1.4 percent), retinal peripheral degeneration (1,4 percent), macroaneurysm (1.4 percent), bilateral papilledema (1.4 percent) and vitreous-retinal traction (1.4 percent). CONCLUSIONS: Patients with AIDS and neurotoxoplasmosis may present fundoscopic abnormalities characteristic of ocular toxoplasmosis, either in active or in scar form, related to HIV or even to other opportunist or systemic diseases, which can be of great aid for integral treatment of patients by a multiprofessional team.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , AIDS-Related Opportunistic Infections , Eye Diseases/etiology , Toxoplasmosis, Cerebral/complications , AIDS-Related Opportunistic Infections/diagnosis , Eye Diseases/diagnosis , Fundus Oculi , Ophthalmoscopy , Prospective Studies , Toxoplasmosis, Cerebral/diagnosis , Toxoplasmosis, Ocular/diagnosis , Toxoplasmosis, Ocular/etiology , Visual Acuity , Young Adult
16.
Arq. bras. oftalmol ; 72(2): 146-151, mar.-abr. 2009. ilus
Article in Portuguese | LILACS | ID: lil-513879

ABSTRACT

OBJETIVOS: Aplicação da técnica de contraste cromático em exames de fundo de olho com oftalmoscópios indiretos. Apresentamos neste trabalho testes preliminares de um novo sistema de iluminação para oftalmoscópios indiretos, elaborado a partir de técnicas de composição cromática, denominado Sistema de Iluminação Cromático, que permite a composição de cores de luz situadas dentro do espectro visível. A finalidade deste sistema é permitir o uso da técnica de cromaticidade, já estudada em outras áreas da medicina como odontologia e dermatologia, na visualização de fundo de olho em exames de oftalmoscopia indireta. MÉTODOS: Para desenvolvimento deste trabalho foi adquirido um oftalmoscópio comercial comum e de uso geral. O equipamento teve seu sistema de iluminação original de fábrica, composto de uma fonte de luz branca alógena e filtros verde e azul, substituído pelo novo sistema de iluminação cromático implementado neste projeto. RESULTADOS: Foram realizados testes preliminares em um olho mecânico que simula as mesmas características de um olho humano biológico in vivo. Os resultados confirmam a possibilidade de obter-se luz em diferenciados comprimentos de ondas através do uso de fontes de luz independentes nas cores vermelho, verde e azul, para uso em instrumentação oftálmica. Embora exames in vivo com pacientes que possuam doenças de retina ainda estejam em fase de testes em nosso laboratório no IFSC-USP & UNIFESP, os resultados preliminares obtidos aqui demonstram que a técnica de contraste cromático para exames de fundo de olho pode futuramente representar um diferencial na qualidade dos exames de oftalmoscopia indireta. CONCLUSÃO: Foi apresentado neste trabalho o desenvolvimento de um sistema de iluminação totalmente inovador para aplicação em oftalmoscopia. Através dos diferentes contrastes e brilhos nas imagens de fundo de olho proporcionados pelas diferentes cores do sistema de iluminação cromático, acreditamos que em uma próxima...


PURPOSE: Chromatic contrast is a technique used in some areas of medicine to provide better visualization of biological tissues. Based on principles of color composition, a new illumination system was constructed using colored emitting diodes to reproduce the spectral range of visible light. This technique was devised to be used in indirect ophthalmoscopes to improve the visualization of the posterior segment of the eye. METHODS: The original illumination system of a general purpose indirect ophthalmoscope was substituted by a system of color-emitting diodes. RESULTS: Using an electronic interface it was possible to control the intensity of the color lights and therefore generate different wavelengths in the visible spectrum of the light. Preliminary tests undertaken in a mechanical model of the human eye generated very clear and homogenous colors. However in vivo examinations with patients were performed in our laboratory at the IFSC-USP and UNIFESP, and obtained the preliminary results show the possibilities of the chromatic contrast technique, and may represent in the future a differential in the analyses of the posterior segment of the eye. CONCLUSION: The use of color-emitting diodes to reproduce the spectral range of the visible light in indirect ophthalmoscopes seems to be a promising technological advance in the fundoscopy of the eye. This is an innovation that can yield better quality examinations with indirect ophthalmoscopes.


Subject(s)
Humans , Color , Fundus Oculi , Lighting/methods , Ophthalmoscopes , Ophthalmoscopy/methods , Equipment Design
17.
Arq. bras. oftalmol ; 72(2): 257-260, mar.-abr. 2009. ilus
Article in English | LILACS | ID: lil-513902

ABSTRACT

Familial exudative vitreoretinopathy (FEVR) is an inherited blinding condition characterized by abnormal development of the retinal vasculature. The authors describe a rare case of the disease associated with severe infantile osteoporosis in a young female patient. The patient was submitted to multiple vitreoretinal procedures in both eyes due to tractional macular detachments. The case was complicated by diffuse uveitis of difficult control in one eye, which stimulated proliferative vitreoretinopathy and retinal redetachment. The inflammatory potential of drugs used in the control of the osteoporosis, in contrast with the inherent inflammatory activity the disease, are discussed.


Relato de um caso incomum de vitreorretinopatia exsudativa familiar (FEVR) bilateral em criança do sexo feminino portadora de grave osteoporose infantil. A paciente foi submetida a vitrectomias sucessivas para correção de descolamentos tracionais maculares em ambos os olhos. O quadro foi complicado em um olho por uveíte difusa de difícil controle, que estimulava o aparecimento de proliferação vitreorretiniana de difícil abordagem, responsável por redescolamentos sucessivos da retina. Discute-se sobre o potencial pró-inflamatório de drogas usadas no controle da osteoporose, em contraste com a atividade inflamatória inerente à doença.


Subject(s)
Child , Female , Humans , Osteoporosis/complications , Retinal Detachment/etiology , Vitreoretinopathy, Proliferative/etiology , Recurrence , Retinal Detachment/surgery , Severity of Illness Index , Vitrectomy , Vitreoretinopathy, Proliferative/diagnosis , Vitreoretinopathy, Proliferative/surgery
18.
Rev. Soc. Bras. Clín. Méd ; 6(6): 219-223, nov.-dez. 2008. tab
Article in Portuguese | LILACS | ID: lil-502520

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A hipertensão arterial sistêmica (HAS) é conhecidamente uma das principais doenças relacionadas à doença renal crônica. Muitos estudos têm demonstrado uma correlação entre as lesões ateroscleróticas no fundo do olho e o grau de aterosclerose renal, secundário à hipertensão arterial, validando este dado como uma importante rotina semiotécnica para a depuração de nefropatias em hipertensos. O objetivo deste estudo foi verificar a presença de correlação entre esses dois acometimentos. MÉTODO: Foram selecionados 30 pacientes baseados nos critérios de inclusão do estudo. A depuração da creatinina e a microalbuminúria foram utilizadas para avaliar a presença de nefropatia. Alterações retinianas foram estabelecidas pela oftalmoscopia indireta. As correlações foram estudadas pelo método de Spearmam. Análise de múltipla Variância e o teste do Qui-quadrado foram empregados para estabelecer o impacto dos diversos fatores sobre as variáveis. RESULTADOS: 68,2% dos pacientes com retinopatia apresentaram nefropatia hipertensiva (NH), enquanto que 41,7% dos nefropatas tinham também retinopatia hipertensiva (RH) (x2 = 4,75; p < 0,05). Fatores de risco para aterosclerose, fármacos utilizados e os sintomas nefrológicos não diferiram entre os grupos. Pacientes com concomitância de NH e RH, apresentaram valores mais elevados de microalbuminúria quando comparados ao grupo sem acometimento e ao grupo com NH. Detectou-se correlação significativa entre essas complicações (r = 0,42; p < 0,05). CONCLUSÃO: A retinopatia hipertensiva na população estudada, apresentou correlação com a ocorrência da nefropatia hipertensiva. O encontro de alterações microvasculares em pacientes hipertensos, na fundoscopia, sugere investigação da lesão renal.(AU)


BACKGROUND AND OBJECTIVES: Hypertension is a commonly cited cause for declining renal function. Presence of retinal arteriolar abnormalities has been postulated to represent an indicative of systemic microcirculatory damage and renal dysfunction secondary to hypertension. Demonstration of this microvascular damage may provide a useful indicator of at-risk individuals for progressive renal function decline. The purpose of this investigation is to describe the associations between these abnormalities. METHODS: Thirteen patients were recruited based in the inclusion conditions of the study. Glomerular filtration rate and the microalbuminuria were used to evaluate the nephropathy presence. Retinal arteriolar abnormalities were evaluated by using indirect fundoscopy. Correlations were examined by using Spearman correlation test. Test of Multiple Variance and Chi-square test were used to establish the impact of the several factors on the variables. RESULTS: 68.2% of patients with retinopathy showed hypertensive nephropathy (HN), while 41.7% of patients with nephropathy also had hypertensive retinopathy (HR) (x2 = 4.75; p < 0.05). Risk factors for arteriosclerosis, used medications and the nephrological symptoms did not differ among the groups. Cases with both complications (HN + HR), presented higher values of microalbuminuria as comparedto those without HR, with or without HN. Significant correlation was detected between the 2 complications (r = 0.42; p < 0.05). CONCLUSION: This investigation shows correlation between the presence of HR and HN. Presence in the fundoscopy of such retinal microvascular abnormalities, in hypertensive patients, suggests screening for renal dysfunction.(AU)


Subject(s)
Humans , Renal Insufficiency, Chronic/physiopathology , Fundus Oculi , Hypertension/etiology , Nephrosclerosis , Ophthalmoscopes , Creatinine/urine , Albuminuria/urine , Hypertensive Retinopathy/diagnosis
19.
Arq. bras. oftalmol ; 70(4): 577-580, jul.-ago. 2007. ilus
Article in English | LILACS | ID: lil-461942

ABSTRACT

PURPOSE: To report some cases of ocular histoplasmosis-like syndrome from a nonendemica area. DESIGN: Observational case series. METHODS: This is a prospective study of 16 eyes from 8 immunocompetent patients evaluated between January 2001 to September 2005. Six patients were female and 2 male aged between 20 to 44 years, average 28 years. All patients presented clinical features that resembled ocular histoplasmosis. All patients had a negative antibody test for histoplasmosis and negative medical and laboratory evaluation of toxoplasmosis, syphilis, and tuberculosis. All patients were submitted to a complete ocular examination including fluorescein angiography. One patient was submitted to indocyanine green angiography. RESULTS: Five patients presented the classical triad of clinical features that include peripapillary scarring, histo spots, choroidal neovascularization, one patient presentd enlargement of atrophic chorioretina scar, one patient presented multiple retinal pigment epithelial detachment, one, neovascularized retinal pigment epithelial detachment. Another patient presented only histo spots. CONCLUSION: These findings of ocular histoplasmosis-like syndrome in patients with negative antibody serum test from a nonendemica area suggest that other agents could cause these similar fundus findings of ocular histoplasmosis.


OBJETIVO: Descrevemos os achados clínicos oftalmológicos de 16 olhos de 8 pacientes imunocompetentes que apresentavam características fundoscópicas da síndrome de histoplasmose ocular. MÉTODOS: Os pacientes foram submetidos aos exames oculares de rotina e ainda à fluoresceinografia e à indocianinografia, além de exames laboratoriais para histoplasmome, toxoplasmose, sífilis, síndrome de insuficiência imunológica adquirida, tuberculose. RESULTADOS: Os exames fundoscópicos, fluoresceinográficos e indocianinográficos demonstraram múltiplas coroidites em saca-bocado, atrofia peripapilar e neovascularização de coróide. Os exames laboratoriais foram considerados normais. CONCLUSÃO: Uma outra etiologia que não a histoplasmose pode ser considerada para os achados encontrados. Uma micobactéria atípica ou o Mycobacterium avium que causam lesões semelhantes às descritas nos exames oculares podem ser consideradas.


Subject(s)
Adult , Female , Humans , Male , Eye Infections, Fungal/diagnosis , Histoplasmosis/diagnosis , Fluorescein Angiography , Prospective Studies , Syndrome
20.
Arq. bras. oftalmol ; 69(6): 941-944, nov.-dez. 2006. ilus
Article in Portuguese | LILACS | ID: lil-440438

ABSTRACT

Relato de caso de um paciente com telangiectasia justafoveal idiopática (TJI) tipo 1A, no olho direito, submetido a 4 mg de triancinolona intravítrea. O resultado foi avaliado por meio da acuidade visual e da tomografia de coerência óptica. A acuidade visual e a espessura retiniana macular medida na tomografia de coerência óptica, antes da injeção intravítrea de triancinolona, foram respectivamente de 20/100 e 569 æm e, após três semanas do tratamento foram de 20/60 e 371 æm e na sexta semana de 20/100 e 614 æm. A estabilização da parede vascular obtida com injeção intravítrea de triancinolona proporciona melhora transitória da visão e do edema macular em olhos com TJI-1A. Não foi demonstrada nenhuma ajuda permanente à fotocoagulação prévia.


Case report of one idiopathic juxtafoveal telangiectasis (IJT) 1A patient whose right eye was treated with a 4 mg intravitreal triamcinolone acetonide injection. The outcome was evaluated by visual acuity and optic coherence tomography. The visual acuity and the caliper retinal thickness before triamcinolone injection were respectively 20/100 and 569 æm, and 20/60 and 371 æm after three weeks and 20/100 and 614 æm after six week of follow-up. The stabilization of the vascular wall due to the intravitreal triamcinolone injection leads to a transitory improvement in vision and reduction in macular edema in the TJI 1A eyes. No permanent help by the photocoagulation could be shown.


Subject(s)
Humans , Male , Middle Aged , Glucocorticoids/administration & dosage , Retinal Diseases/drug therapy , Retinal Vessels/drug effects , Telangiectasis/therapy , Triamcinolone Acetonide/administration & dosage , Injections , Macular Edema/drug therapy , Retinal Vessels/pathology , Time Factors , Visual Acuity , Vitreous Body/drug effects
SELECTION OF CITATIONS